Wir verwenden Cookies, um für diese Website Funktionen wie z.B. Login, einen Warenkorb oder die Sprachwahl zu ermöglichen. Weiterhin nutzen wir für anonymisierte, statistische Auswertungen der Nutzung Google Analytics, welches Cookies setzt. Mehr Informationen finden Sie in unserer Datenschutzerklärung.
OK, ich bin einverstanden Ich möchte keine Google Analytics-Cookies
The International Journal of Oral & Maxillofacial Implants
Login:
Benutzername:

Kennwort:

Plattform:

Kennwort vergessen?

Registrieren

Int J Oral Maxillofac Implants 32 (2017), Nr. 3     19. Mai 2017
Int J Oral Maxillofac Implants 32 (2017), Nr. 3  (19.05.2017)

Online Article, Seite e119-e124, doi:10.11607/jomi.5174, PubMed:28231345, Sprache: Englisch


Online Article: In Vitro Evaluation of Three Methods for the Retrieval of Fractured Screw Fragments from Dental Implants
Agustín-Panadero, Rubén / Labaig-Rueda, Carlos / Castillo-Rodriguez, Beatriz / Ferreiroa, Alberto / Solá-Ruíz, María Fernanda
Purpose: To compare the effectiveness of different methods of fractured screw fragment retrieval from dental implants, comparing a conventional method (use of an exploration probe and ultrasonic tips) with two mechanical retrieval kits.
Materials and Methods: One hundred thirty-five screws in implant internal connections were fractured to test fragment retrieval comparing three methods: conventional method with the use of an explorer probe and ultrasonic tips (group CE), extraction with a mechanical kit with a guide cylinder (group MK1), and extraction with a mechanical kit without a guide cylinder (group MK2). Extraction success and retrieval times for each method, as well as success and retrieval times in relation to fracture depth-coronal, middle, or apical-were analyzed by means of chi-square, Fisher exact, Kruskal-Wallis, and Mann-Whitney tests (P < .05). The integrity of implant internal threads was also analyzed.
Results: The extraction success rates for groups MK2, CE, and MK1 were 93.3%, 73.3%, and 20%, respectively. The mean ± SD extraction times were 2 minutes, 56 seconds ± 2 minutes, 9 seconds; 3 minutes, 15 seconds ± 1 minute, 48 seconds; and 13 minutes, 34 seconds ± 7 minutes, 25 seconds for groups MK2, CE, and MK1, respectively. Statistically significant differences were found in the number of fractured screws extracted and in the retrieval time. No significant differences were found for retrieval time or extraction success in relation to the depth of the fracture.
Conclusion: The mechanical kit without the guide cylinder achieved the best results with respect to the number of screw fragments retrieved, retrieval time, and preservation of implant internal threads.

Schlagwörter: fragment screw, implant, mechanical kits, prosthetic