Wir verwenden Cookies, um für diese Website Funktionen wie z.B. Login, einen Warenkorb oder die Sprachwahl zu ermöglichen. Weiterhin nutzen wir für anonymisierte, statistische Auswertungen der Nutzung Google Analytics, welches Cookies setzt. Mehr Informationen finden Sie in unserer Datenschutzerklärung.
OK, ich bin einverstanden Ich möchte keine Google Analytics-Cookies
The International Journal of Oral & Maxillofacial Implants
Login:
Benutzername:

Kennwort:

Plattform:

Kennwort vergessen?

Registrieren

Int J Oral Maxillofac Implants 33 (2018), Nr. 5     4. Okt. 2018
Int J Oral Maxillofac Implants 33 (2018), Nr. 5  (04.10.2018)

Seite 967-978, doi:10.11607/jomi.6348, PubMed:30231082, Sprache: Englisch


A Novel Experimental Dental Implant Permits Quantitative Grading of Surface-Property Effects on Osseointegration
Hunziker, Ernst B. / Spiegl-Habegger, Michael / Rudolf, Stefanie / Liu, Yuelian / Gu, Zhiyuan / Lippuner, Kurt / Shintani, Nahoko / Enggist, Lukas
Purpose: To test the hypothesis if a novel single-chamber experimental dental implant allows in vivo the quantitative assessment of osseointegration over time and as a function of different surface properties (physical, chemical, geometric, biologic [osteoconductive or osteoinductive]) in a biologically unfavorable environment (local osteoporosis).
Materials and Methods: Three prototypes of a novel experimental implant with different chamber sizes (small, medium, and large) were compared with each other to find out the minimum size of bone chambers needed to allow a discriminative quantification of osseointegration over time. For the comparison of low and high surface osteoconductivity properties, conventional sandblasted, acid-etched chamber surfaces (low surface osteoconductivity) were compared with biomimetically (calcium phosphate) coated ones (high surface osteoconductivity). The implants (4 implants per animal; 88 implants per time point) were inserted into the edentulous maxillae of a total of 66 adult goats with a physiologically osteoporotic masticatory apparatus. Two, 4, and 8 weeks later, they were excised and prepared for a histomorphometric analysis of the volume of neoformed bone within the chamber space and of the bone-to-implant contact (BIC) area.
Results: The implants with small chambers did not show significant differences in bone coverage (BIC) nor bone volume (relative and absolute volume), neither as a function of time nor as of implant surface property (low versus high surface osteoconductivity). However, medium and large chambers revealed significant differences respecting both of these parameters over the 8-week postoperative time period.
Conclusion: The new implant model permits a discriminative quantification of osseointegration in vivo in an osteoporotic bone environment for implants with medium-sized and large-sized chambers. Quantitative assessment of osseointegration is possible, both over time and as a function of low and high surface osteoconductivity properties.

Schlagwörter: animal experiments, bioactive surface, experimental implant, osseointegration, quantification, surface chemistry