Int J Oral Maxillofac Implants 35 (2020), No. 3     26. May 2020
Int J Oral Maxillofac Implants 35 (2020), No. 3  (26.05.2020)

Page 639-644, doi:10.11607/jomi.7990, PubMed:32406664


Zirconium Implant as an Alternative to Titanium Implant in a Case of Type IV Titanium Allergy: Case Report
Tawil, Georges / Tawil, Peter / Irani, Carla
Titanium remains the material of choice in the manufacturing of dental implants because of its exceptional biologic and mechanical properties. However, cases of allergy to titanium have been reported in the literature causing skin, mucosal reactions, systemic symptoms, and eventually implant exfoliation. Although the frequency of these cases varied between 0.6% and 5%, undiagnosed or misdiagnosed cases may possibly increase this percentage significantly. Epicutaneous, intradermal inoculation of the allergen or blood tests (LTT, MELISA, IL1β, IL-6, TNF-α, IL-10) have been used with various degrees of sensitivity and specificity to assess Ti allergy. This case report demonstrated that titanium dental implant allergy caused rapid implant loss following an acute inflammatory reaction and its successful replacement by a one-piece zirconium implant.

Keywords: osseointegration, titanium allergy, zirconium implants