Wir verwenden Cookies, um für diese Website Funktionen wie z.B. Login, einen Warenkorb oder die Sprachwahl zu ermöglichen. Weiterhin nutzen wir für anonymisierte, statistische Auswertungen der Nutzung Google Analytics, welches Cookies setzt. Mehr Informationen finden Sie in unserer Datenschutzerklärung.
OK, ich bin einverstanden Ich möchte keine Google Analytics-Cookies
The International Journal of Oral & Maxillofacial Implants
Login:
Benutzername:

Kennwort:

Plattform:

Kennwort vergessen?

Registrieren

Int J Oral Maxillofac Implants 28 (2013), Nr. 6     20. Dez. 2013
Int J Oral Maxillofac Implants 28 (2013), Nr. 6  (20.12.2013)

Online Article, Seite 349-356, doi:10.11607/jomi.te15, PubMed:24278938, Sprache: Englisch


Online Article: Recombinant Human Bone Morphogenetic Protein-2 Confined by an Imperforate Titanium Shell over High-Profile Dental Implants in Rabbit Tibiae: A Pilot Bone Augmentation Study
Casap, Nardy / Laster, Zvi / Laviv, Amir / Debecco, Meir / Alterman, Michael / Cottam, Jared / Jensen, Ole T.
Purpose: To evaluate the use of a nonperforated titanium occlusive device over a bone morphogenetic protein-2 in an absorbable collagen sponge (BMP-2/ACS) in grafting the bone around high-profile (ie, supracrestal) dental implants in rabbit tibiae.
Materials and Methods: Eight New Zealand white rabbits were used for the experiment. Two implants were placed in the right tibia of each rabbit, with 4 mm of each implant placed supracrestally ("high-profile" placement) in four groups of two rabbits each: control, titanium shell only, titanium shell over buffered collagen, and titanium shell over BMP-2/ACS. The animals were sacrificed after 3 or 6 weeks. Calcified and nondecalcified histologic preparation was carried out to evaluate bone formation and degree of osseointegration.
Results: Three of the eight animals developed tibial fractures. The two BMP-2 test animal tibiae remained intact, with the 3-week specimen showing very little bone formation inside or outside of the titanium chamber and the 6-week specimen showing bone mostly outside of the chamber.
Conclusion: The placement of BMP-2 beneath an occlusive nonperforated titanium shell next to a high-profile implant did not result in significant bone formation.